June 2006 Installation Guide
15
Each MTAS shelf requires three (3) Rack Units or 5.25 inches of vertical rack space.
The MTAS shelves may be installed directly above or below one another: there is no
vertical spacing required for cooling or cabling.
2.8 Unpacking
The MTAS is shipped in two separate boxes – one contains the MTAS-192 shelf, and
the other contains the circuit packs for the shelf. There are no special handling
requirements for the shelf; however, the circuit packs require standard ESD handling
precautions.
CAUTION: A grounded wrist strap should be worn at all times when handling the circuit
packs. Place cards in or on static bags when working with the cards.
NOTE: After unpacking, do not install the circuit packs into the shelf before the shelf is
mounted in the equipment rack. Mount the MTAS-192 shelf in the rack before inserting
circuit packs.
2.9 Inspection
Step 1. Using standard ESD handling precautions unwrap circuit cards one at a time.
Step 2. Consult the packing list (see section 2.10 Packing List) to verify that all items
have been received as ordered and inspect them for obvious physical damage.
Step 3. If there is damage, re-pack the item in the shipping materials in which it came
in and return to Comtest Networks using the standard defect return procedure
in Appendix B: Repair and Return Services.
Step 4. If there is no damage, go to Chapter 3: Installing the MTAS Shelf.
2.10 Packing List
Please verify the contents of your MTAS-192 shipment against the packing list(s).
2.10.1 Shelf
One (1) MTAS-192 High Density, Test Access Shelf
Two (2) universal ANSI ear mounts (flanges) for either 19 or 23" shelves, each
supplied with two (2) screws and two (2) washers
One (1) ISCL bus terminator (RJ-45 connector 'dongle')
One (1) Steward EMI (Electro-magnetic Interference) suppressor
Optional Redundant Power Feed Steward EMI suppressor
Optional RJ-21 Hex Nut kits
Optional RJ-21 Angle Shroud kits.
NOTE: Hex Nut and Angle Shroud kits are based on the RJ-21 shroud type (D-type or
Angled) and screw length (0.75" or less than (<) 0.75") used to build the CAT5 RJ-21
24-pair cables that connect to the MTAS backplane POTS, Line, and line card DSL